Your home with this consumer unit
Consumer unit S · Standard · flush-mounted · door: oak · air conditioning 1 × split 3.5 kW
- Solar PVInverter section and DC combiner box — in the spare space or in the PV version.See the PV version
- Home batteryAdd the battery section together with solar PV.See the PV version
- Electric carCharger circuit with a Type B RCD (residual current device) — in the EV version.See the EV version
- Heat pumpAdd a dedicated heat pump circuit in the configurator.Add in the configurator
Can be added — add it in the configurator.
Consumer unit S · Standard · flush-mounted · door: oak · air conditioning 1 × split 3.5 kW
Flat or small house up to about 80 m² with one kitchen — without solar PV or EV charger, replacing an old board with a new one with surge protection.
Size S — flat or small house up to approx. 80 m², about 10 circuits. 36-module enclosure: 3 rows · 2 RCD groups
without solar PV or EV charger
Air conditioning supply
Add circuits for split air conditioners — a C-curve RCBO with 30 mA protection for each outdoor unit up to 3.5 kW.
Other power, multi-split or three-phase — in the configurator.
Smart home, KNX, or an industrial or special switchboard? Quoted individually — Describe the installation.
PLN 3,148.80incl. 23% VAT · PLN 2,560.00 excl. VAT · excluding delivery
Delivery and installation in Poland only
The flush-mounted enclosure is new in our range — the price is from today’s price list and we confirm it when we check your order.
- 10 circuits
- 2 RCDs and a T2 surge protection device
- 3 rows, 36 modules
Lead time: 5–10 working days from receipt of the deposit. Production starts after we check your order (usually 1 working day). Building a house? At checkout you can choose staged delivery: the back box first, before plastering, and the devices later.
Product datasheet (PDF) — dimensions and wall opening, circuits, simplified diagram
Have a question about this product?Ask us — we reply within 1 working day
10 circuits in 2 groups of 4-pole Type A RCDs (30 mA), induction hob on a 3-phase circuit, T2 surge protection. 36-module enclosure (3 rows × 12), devices take 28 — 22% spare.
- Main switch, surge protection device, phase indicators, N/PE terminal bars8 mod.
- 4-pole Type A residual current devices (RCDs) × 2 (circuit groups)8 mod.
- Circuit breakers (MCBs) × 10 (sockets, lighting, appliances; induction hob — 3-phase)12 mod.
- Flush-mounted enclosure (back box for building into the wall, frame with door)—
- Door: oak—
- Air conditioning — split 3.5 kW circuit: RCBO C10 30 mA Type A2 mod.
- Enclosure
- 36 modules — flush-mounted (back box for building into the wall, frame with door), 3 rows of DIN rail
- Wall opening
- 360 × 615 mm (W × H), recess depth 89 mm — max. of the enclosures of the brands we build with (Hager, Schneider Electric, Eaton)
- Minimum wall thickness
- 110 mm
- Frame with door
- 400 × 631 mm — visible on the wall
- Enclosure weight
- up to 2,2 kg (enclosure only, without devices)
- Door
- Oak — Wood-effect veneer in natural oak.
- DIN modules
- 30 used of 36 (spare 6)
- Circuits
- 10 (max. 12 in this enclosure)
- Residual current devices (RCDs)
- 2 × 4-pole 40 A, 30 mA, Type A — circuits split into groups
- Surge protection device (SPD)
- T2
- Standard
- EN 61439-3 (PN-EN 61439-3), the enclosure and switchgear manufacturer's verified system
- Lead time
- 5–10 working days from the deposit
Wiring diagram
A single-line diagram of the consumer unit with device labels — for signing off the house, for your insurer and for any electrician who opens it in the future.
Circuit chart
A clear list of which breaker supplies which room or appliance. Stuck inside the door and supplied as a PDF.
Routine verification report
Test results: continuity of protective conductors, insulation resistance and RCD operation — to EN 61439-3 (PN-EN 61439-3).
EU declaration of conformity
The manufacturer’s document confirming compliance with the Low Voltage Directive and EN 61439-3.
24-month warranty
Covering workmanship and devices. The unit’s serial number identifies its documentation for 10 years.
Spare space for expansion
The configurator keeps 10% of the space free, so you can add a charger or battery without replacing the consumer unit.
Technical documents for the consumer unit (wiring diagram, test report) are issued in Polish, as required for products installed in Poland.
Collection — PLN 0
From our workshop in Warsaw, by appointment. 100% deposit when you order.
Courier delivery (Poland) — PLN 99 excl. VAT
The consumer unit is packed on a pallet or in a box, with the documents inside. Your electrician installs it.
Installation with board replacement and testing — PLN 1,490 excl. VAT within 50 km
Beyond that, PLN 2 per km each way. For installation in a residential building, VAT is 8% (we confirm this when we check your order) and the deposit is 50%.
Production starts after the check
Paying the deposit doesn't start production — first we check your supply capacity, network type and device models (usually 1 working day).
Do we install at your address? Check by postcode